CVE-2024-3082
A “CWE-256: Plaintext Storage of a Password” affecting the administrative account allows an attacker with physical access to the machine to retrieve the password in cleartext unless specific security measures at other layers (e.g., full-disk encryption) have been enabled.
Clear text password extraction might be possible.
July 7, 2023
Sensor Net Connect V2 (FW version 2.24)
CVE-2024-3082
CVSS:3.1/AV:P/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N
4.2
No official patch available from vendor. Implement strict access controls for the temperature monitoring infrastructure. This includes preventing regular clients from accessing the web configuration interface, thereby limiting potential points of exploitation. Conduct regular and thorough reviews of logs and user accounts on systems running the Thermoscan IP software. This will help identify and address any suspicious activities early, ensuring that any potential security breaches are caught and remediated swiftly.
Diego Zaffaroni of Nozomi Networks
Nozomi Networks Labs curates threat and vulnerability insights that are continuously fed into the Nozomi Networks platform to ensure our sensors can detect existing and emerging threats and vulnerabilities that threaten customers environments.
Learn more