CVE-2024-50375
A CWE-306 “Missing Authentication for Critical Function” was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability can be exploited by remote unauthenticated users capable of interacting with the default "edgserver" service enabled on the access point.
The vulnerability can be exploited by unauthenticated users to executed arbitrary commands with root privileges on the device.
November 26, 2025
The following products and firmware versions are affected: EKI-6333AC-2G ≤ v1.6.3 EKI-6333AC-2GD ≤ v1.6.3 EKI-6333AC-1GPO ≤ v1.2.1
CVE-2024-50375
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8
Update affected products to the following firmware versions released by Advantech: - EKI-6333AC-2G: v1.6.5 - EKI-6333AC-2GD: v1.6.5 - EKI-6333AC-1GPO: v1.2.2
Diego Zaffaroni of Nozomi Networks
Nozomi Networks Labs curates threat and vulnerability insights that are continuously fed into the Nozomi Networks platform to ensure our sensors can detect existing and emerging threats and vulnerabilities that threaten customers environments.